Skip to content
XIMED

Technology

Phase-contrast X-ray imaging

A new generation of X-ray imaging that looks beyond absorption, designed to reveal the fine structure of breast calcifications.

The principle

Beyond absorption: measuring the phase shift.

Conventional mammography relies on measuring the absorption of X-rays by breast tissues. Because the different tissue types absorb X-rays in very similar ways, image contrast is often limited, making subtle structures difficult to distinguish.

XIMED’s patented technology takes imaging a step further through X-ray phase-contrast imaging. In addition to absorption information, it captures the phase shifts that occur when X-rays pass through tissue interfaces. This innovative approach reveals extremely fine structural details, including microcalcifications and other subtle anatomical features that may be difficult to detect with conventional imaging alone.

Micro-focus sourceSpatially coherentObjectAbsorption modePhase-contrast mode
Fig. 1Propagation-based geometry: when the detector is positioned close to the object, the image primarily reflects X-ray absorption. As the detector is moved farther away, interference fringes emerge at tissue interfaces.

Absorption or phase contrast

Fine structural details, barely visible in mammography.

The same breast specimen, imaged by conventional mammography and then in phase contrast by XIMED, as part of the CLEAR-BX clinical study.

The same specimen in phase contrast imaging: in both outlined areas, the microcalcifications and tissue outlines appear sharply.
Phase contrast imaging
Breast specimen in standard absorption imaging: two areas are outlined, the microcalcifications in them are barely visible.Standard absorption imaging
CLEAR-BX clinical study, ICO.

Intellectual property

A patented technology

The same principle underpins both XIMED products: BRIGHTX for breast specimens, and PHOENIX, under development, for in-vivo breast imaging.

Heritage

Born from XPulse

XIMED technology was developed as part of XPulse, a regional strategic project driving innovation in X-ray phase-contrast imaging for mammography.

XPulse consortium

  • ALPhANOVPhotonics research and technology centre
  • CELIAResearch laboratory in lasers, plasmas and photonics (CNRS / Univ. Bordeaux / CEA)
  • AmplitudeManufacturer of high-performance laser systems
  • Imagine OpticWavefront metrology and adaptive optics specialist
  • Institut BergoniéComprehensive cancer centre, Bordeaux

Funded by Région Nouvelle-Aquitaine

Clinical studies

What is being measured today, with our clinical partners.

BRIGHTX is being assessed in two ongoing clinical studies at the Institut de Cancérologie de l'Ouest. Their results have not yet been published.

XIMED clinical studies
StudyCentreDesignStatus
CLEAR-BXICO Angers and Saint-Herblain (Nantes)54 breast macrobiopsy lesions, 541 cores, each read in conventional mammography, with BRIGHTX and in pathologyOngoing: inclusions complete (September 2026), results not yet published
DISCERN-BXICO Nantes and AngersProtocol to be announcedOngoing

Microcalcification clusters, in phase contrast.

  • Phase-contrast image of a breast specimen with microcalcifications: CIS. Scale bar: 500 µm.

    CIS

  • Phase-contrast image of a breast specimen with microcalcifications: Benign. Scale bar: 500 µm.

    Benign

  • Phase-contrast image of a breast specimen with microcalcifications: Benign. Scale bar: 500 µm.

    Benign

  • Phase-contrast image of a breast specimen with microcalcifications: Apocrine DCIS. Scale bar: 500 µm.

    Apocrine DCIS

  • Phase-contrast image of a breast specimen with microcalcifications: Malignant in situ. Scale bar: 500 µm.

    Malignant in situ

  • Phase-contrast image of a breast specimen with microcalcifications: Malignant in situ. Scale bar: 500 µm.

    Malignant in situ

  • Phase-contrast image of a breast specimen with microcalcifications: MCA / HCA. Scale bar: 500 µm.

    MCA / HCA

  • Phase-contrast image of a breast specimen with microcalcifications: Benign. Scale bar: 500 µm.

    Benign

  • Phase-contrast image of a breast specimen with microcalcifications: Fibroadenomatous hyperplasia. Scale bar: 500 µm.

    Fibroadenomatous hyperplasia

Phase-contrast acquisitions of breast specimens, XIMED / ICO.

See phase contrast at work in BRIGHTX

Our team can walk you through the principle, the first images from the CLEAR-BX study and the BRIGHTX system.